Case Study

Gottwald Crane

Gottwald Crane

Wire Bogey Assembly

We were engaged at 17:00 on a Friday evening to perform reactive works on a major cargo handling crane.

With three ships awaiting discharge, we had to arrange many areas swiftly.

Within twelve hours the following components were either refurbished or manufactured following careful dismantling:-

  • EN24 Pin – turned to 140mm diameter head size. Pin turned to 120mm diameter bearing size. Drilled through and tapped both ends 1/4 BSP. Keep plate slot milled. Grease way drilled.
  • Bearing shields – manufactured x2. Turned outer diameter location. Drilled and bored 120mm diameter clear. Drilled x8 9mm diameter holes on a 200 pitch circle diameter. Counter sunk to accept new screws. Material – EN8- 230mm diameter, 30mm thick.

Reactive tasks like this are ‘bread and butter’ to us. Don’t hesitate we are here 24hours a day. One hourly rate!

We can help you too

We're up for the challenge!

Hickman Engineering prides itself on undertaking works that are considered too challenging for other firms. Whether this is a small project or large we offer a set rate 24/7 coverage which is available to all of our clients. Challenge us to come up with your solution.